Eljer 015-0005 Specifications Page 7

  • Download
  • Add to my manuals
  • Print
  • Page
    / 9
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 6
TOTAL MASSAGE AND AIR BATH CONTROL PAD
Total Massage units are a combination of a whirlpool and air bath. The Total Massage control pad contains six (6) buttons.
The top three controls on the “Therapy Control Center” operate the whirlpool and the bottom three controls operate the air
system. The whirlpool and air massages systems may be used at the same time if desired.
The air bath is controlled by a three button control:
1. The rst button switches the blower on or off. The other features will not operate unless the blower is turned on.
2. The second button sets the power level of the blower. Holding the button depressed will cycle the blower power from
low to high in a continuous cycle. When the desired level is reached, remove your nger quickly from the button to
maintain that power setting.
3. The third button is a three step wave action button. Once activated, the air holes expell air in a slow pulsating ow
called wave action. There are 3 steps or positions for wave strength.
a. Position #1 operates the blower at a steady ow.
b. Position #2 operates the blower at a quick wave action.
c. Position #3 operates the blower at a slower wave action.
Whirlpool Troubleshooting
MOTOR WILL NOT START:
1. Check circuit breakers.
2. Check for incorrect or loose wire connections.
3. Make sure the correct power supply is being used.
4. On/Off switch should be in the “On” mode.
5. Make sure that the jets are fully opened and water is owing.
MOTOR OVERHEATING AND CYCLING ON AND OFF:
1. Check for incorrect or loose wire connections.
2. Check for low voltage supply (frequently caused by undersized wire).
3. Make sure the motor gets a fresh air supply and the vents are kept unclogged.
MOTOR MAKES HUMMING NOISE BUT WON’T START:
1. Open jets
2. Make sure that the motor shaft turns free.
3. Check for jammed impeller or an obstruction on the (volute) casing.
4. Check for low voltage and undersize wire.
LOW WATER FLOW:
1. Check for clogged plumbing lines.
2. Check for low voltage.
Air Bath Control Pad
-7-
Switches the
jet-pump
on or off
Adjusts the variable
water ow of the jets
Switches from
continuous to wave
action water ow
Switches the
air blower
on or off
Adjusts the variable
air ow of the blower
Switches from
continuous to wave
action air ow
Total Massage Control Pad
Adjusts the variable
air ow of the blower
Switches the
air blower
on or off
Switches from
continuous to wave
action air ow
Page view 6
1 2 3 4 5 6 7 8 9

Comments to this Manuals

No comments